My outdoor AC unit is silent but the indoor fan runs. Is it a big repair?

Answers from the sources

  1. ADRIUM service solutions

    “Usually not. Usually the run capacitor has failed or the contactor is pitted. We test with a meter, replace the part, and verify the compressor and fan motor both pull correct amps before we leave. Some companies quote this symptom as a system problem. It is a small part.”