How does Ecogate maintain minimum transport air velocity while slowing the fan?

Answers from the sources

  1. Ecogate, Inc.

    “Ecogate actively measures minimum transport velocity rather than relying on design estimates. An Averaging Air Velocity Sensor (AAVS) in the main duct measures air velocity in real time.”