{"schemaVersion":"ready-scan.discovery-entity.v3","id":"urn:readyscan:entity:inpulse-animal-health-q140671458","slug":"inpulse-animal-health-q140671458","kind":"entity","entityType":"Organization","canonicalUrl":"https://directory.readyscan.ai/entities/inpulse-animal-health-q140671458","machineUrl":"https://directory.readyscan.ai/discovery/entities/inpulse-animal-health-q140671458.json","llmsUrl":"https://directory.readyscan.ai/entities/inpulse-animal-health-q140671458/llms.txt","name":"INpulse Animal Health","alternateNames":[],"websiteUrl":"https://inpulse.vet/","category":{"slug":"enterprises","name":"Enterprises","canonicalUrl":"https://directory.readyscan.ai/directory/enterprises"},"description":"INpulse Animal Health: “Brazilian connected veterinary technology company. It develops the INcardio X and INcardio Agile electrocardiographs, the BPScan and BPScan S blood pressure monitors and the INmonitor multiparameter monitor, integrated with the INpulse One platform and the INcloud cloud, with referral to partner cardiologists for tele-reporting.”","summary":"INpulse Animal Health: “Brazilian connected veterinary technology company. It develops the INcardio X and INcardio Agile electrocardiographs, the BPScan and BPScan S blood pressure monitors and the INmonitor multiparameter monitor, integrated with the INpulse One platform and the INcloud cloud, with referral to partner cardiologists for tele-reporting.”","localizedDescriptions":[],"claims":[{"id":"content-native-digital-agencies-4eb181f988c7d306-a-e0430757936b26a61ec7","label":"INpulse Animal Health","value":"“Brazilian connected veterinary technology company. It develops the INcardio X and INcardio Agile electrocardiographs, the BPScan and BPScan S blood pressure monitors and the INmonitor multiparameter monitor, integrated with the INpulse One platform and the INcloud cloud, with referral to partner cardiologists for tele-reporting.”","sourceIds":["source-b28b3502b73cd312"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-3d938541130c7cc54dfb","label":"What sets the BPScan S apart?","value":"“The BPScan S is the compact version of the high-definition oscillometric pressure monitor. It keeps the real-time oscillometric waveform and the accuracy of BPScan in a smaller, thinner form, powered solely over USB-C, without an internal battery. It is the option for those who prioritize portability and plug & play use connected to the computer or phone.”","sourceIds":["source-ecf955180b0401eb"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-27c7e244951b05cc451b","label":"Which systems or devices is it compatible with?","value":"“The BPScan S works over USB-C with laptops and PCs and with Android devices. It is not compatible with iOS or with ARM-architecture devices, so confirm the device you will use before purchasing. If in doubt, talk to a specialist to validate compatibility with your setup.”","sourceIds":["source-ecf955180b0401eb"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-38e596ca36fe57a1e119","label":"What is high-definition oscillometry?","value":"“It is the non-invasive method that records pressure oscillations as the cuff deflates. In high definition, you follow the measurement curve live, with the systolic, mean and diastolic markers, instead of trusting only the final number.”","sourceIds":["source-4ef867b2e6265e6b"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-df3c743838ed5aad062a","label":"What is the measuring range of the BPScan?","value":"“From 20 to 280 mmHg, with 1 mmHg resolution.”","sourceIds":["source-4ef867b2e6265e6b"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-cb4dc3de3f5b9c98d296","label":"What is the difference between BPScan and BPScan S?","value":"“The BPScan S is the compact version, with a USB-C connection. Both use the same INpulse One.”","sourceIds":["source-4ef867b2e6265e6b"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-50c5130b1183047a8e43","label":"Where do I see the results?","value":"“In INpulse One: curve, values and history go into the patient record. During monitoring, NIBP also feeds the digital anesthetic chart.”","sourceIds":["source-4ef867b2e6265e6b"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-d8424ee636d9d5fd3567","label":"What affects measurement quality?","value":"“As in all veterinary oscillometry, choosing the cuff appropriate to the patient size and correct positioning are essential for accuracy.”","sourceIds":["source-4ef867b2e6265e6b"]}],"knowledge":{"offerings":[],"answers":[{"id":"content-native-digital-agencies-4eb181f988c7d306-a-3d938541130c7cc54dfb","question":"What sets the BPScan S apart?","answer":"“The BPScan S is the compact version of the high-definition oscillometric pressure monitor. It keeps the real-time oscillometric waveform and the accuracy of BPScan in a smaller, thinner form, powered solely over USB-C, without an internal battery. It is the option for those who prioritize portability and plug & play use connected to the computer or phone.”","sourceIds":["source-ecf955180b0401eb"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-3d938541130c7cc54dfb"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-27c7e244951b05cc451b","question":"Which systems or devices is it compatible with?","answer":"“The BPScan S works over USB-C with laptops and PCs and with Android devices. It is not compatible with iOS or with ARM-architecture devices, so confirm the device you will use before purchasing. If in doubt, talk to a specialist to validate compatibility with your setup.”","sourceIds":["source-ecf955180b0401eb"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-27c7e244951b05cc451b"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-38e596ca36fe57a1e119","question":"What is high-definition oscillometry?","answer":"“It is the non-invasive method that records pressure oscillations as the cuff deflates. In high definition, you follow the measurement curve live, with the systolic, mean and diastolic markers, instead of trusting only the final number.”","sourceIds":["source-4ef867b2e6265e6b"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-38e596ca36fe57a1e119"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-df3c743838ed5aad062a","question":"What is the measuring range of the BPScan?","answer":"“From 20 to 280 mmHg, with 1 mmHg resolution.”","sourceIds":["source-4ef867b2e6265e6b"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-df3c743838ed5aad062a"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-cb4dc3de3f5b9c98d296","question":"What is the difference between BPScan and BPScan S?","answer":"“The BPScan S is the compact version, with a USB-C connection. Both use the same INpulse One.”","sourceIds":["source-4ef867b2e6265e6b"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-cb4dc3de3f5b9c98d296"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-50c5130b1183047a8e43","question":"Where do I see the results?","answer":"“In INpulse One: curve, values and history go into the patient record. During monitoring, NIBP also feeds the digital anesthetic chart.”","sourceIds":["source-4ef867b2e6265e6b"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-50c5130b1183047a8e43"]},{"id":"content-native-digital-agencies-4eb181f988c7d306-a-d8424ee636d9d5fd3567","question":"What affects measurement quality?","answer":"“As in all veterinary oscillometry, choosing the cuff appropriate to the patient size and correct positioning are essential for accuracy.”","sourceIds":["source-4ef867b2e6265e6b"],"claimIds":["content-native-digital-agencies-4eb181f988c7d306-a-d8424ee636d9d5fd3567"]}],"developments":[]},"sources":[{"id":"source-record","title":"INpulse Animal Health website","publisher":"inpulse.vet","url":"https://inpulse.vet/","accessedOn":"2026-10-20"},{"id":"source-b28b3502b73cd312","title":"inpulse.vet/en/","publisher":"inpulse.vet","url":"https://inpulse.vet/en/","accessedOn":"2026-10-20","relatedPublicationsUrl":"https://readyscan.ai/sources/source-b28b3502b73cd312"},{"id":"source-ecf955180b0401eb","title":"inpulse.vet/en/products/bpscan-s/","publisher":"inpulse.vet","url":"https://inpulse.vet/en/products/bpscan-s/","accessedOn":"2026-10-20","relatedPublicationsUrl":"https://readyscan.ai/sources/source-ecf955180b0401eb"},{"id":"source-4ef867b2e6265e6b","title":"inpulse.vet/en/products/bpscan/","publisher":"inpulse.vet","url":"https://inpulse.vet/en/products/bpscan/","accessedOn":"2026-10-20","relatedPublicationsUrl":"https://readyscan.ai/sources/source-4ef867b2e6265e6b"}],"ownership":{"state":"public_sourced_unclaimed","notice":"Public-source record; owner verification is not claimed.","provenance":{"snapshotId":"inpulse-animal-health-q140671458-content-a0673e8d19959be8-snapshot","sourceId":"ready-scan-subjects","sourceRecordId":"Q140671458","sourceRevisionId":"Q140671458:content:f7dc6ef99294a2e8","sourceContentHash":"fnv1a64:a03700d5b6b9cc48","recordRevisionId":"Q140671458:content:f7dc6ef99294a2e8","recordContentHash":"fnv1a64:aa1d26c7d88f8d71","sourceCanonicalUrl":"https://inpulse.vet/","sourceModifiedAt":"2026-10-20T19:52:38.952Z","observedOn":"2026-10-20","permission":{"basis":"public_information","evidenceUrl":"https://inpulse.vet/"},"attributionUrl":"https://inpulse.vet/"}},"datePublished":"2026-10-20","dateModified":"2026-10-20","contentFingerprint":"fnv1a64:43aa734b8087a5a7","revision":"fnv1a64:734ef779abd0f98c","agentProtocol":{"discovery":"https://readyscan.ai/api/v1/ai-search/discovery","evidence":"https://readyscan.ai/api/v1/ai-search/entities/inpulse-animal-health-q140671458/evidence"},"structuredData":{"@context":"https://schema.org","@id":"https://directory.readyscan.ai/entities/inpulse-animal-health-q140671458#entity","name":"INpulse Animal Health","identifier":"urn:readyscan:entity:inpulse-animal-health-q140671458","description":"INpulse Animal Health: “Brazilian connected veterinary technology company. It develops the INcardio X and INcardio Agile electrocardiographs, the BPScan and BPScan S blood pressure monitors and the INmonitor multiparameter monitor, integrated with the INpulse One platform and the INcloud cloud, with referral to partner cardiologists for tele-reporting.”","url":"https://inpulse.vet/","mainEntityOfPage":"https://directory.readyscan.ai/entities/inpulse-animal-health-q140671458","datePublished":"2026-10-20","dateModified":"2026-10-20","citation":["https://inpulse.vet/","https://inpulse.vet/en/","https://inpulse.vet/en/products/bpscan-s/","https://inpulse.vet/en/products/bpscan/"],"additionalProperty":[{"@type":"PropertyValue","propertyID":"ownership-state","name":"Ownership state","value":"public_sourced_unclaimed"},{"@type":"PropertyValue","propertyID":"content-fingerprint","name":"Material content fingerprint","value":"fnv1a64:43aa734b8087a5a7"},{"@type":"PropertyValue","propertyID":"source-record","name":"Source record","value":"ready-scan-subjects/Q140671458"},{"@type":"PropertyValue","propertyID":"source-revision","name":"Source revision","value":"Q140671458:content:f7dc6ef99294a2e8"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-e0430757936b26a61ec7","name":"INpulse Animal Health","value":"“Brazilian connected veterinary technology company. It develops the INcardio X and INcardio Agile electrocardiographs, the BPScan and BPScan S blood pressure monitors and the INmonitor multiparameter monitor, integrated with the INpulse One platform and the INcloud cloud, with referral to partner cardiologists for tele-reporting.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-3d938541130c7cc54dfb","name":"What sets the BPScan S apart?","value":"“The BPScan S is the compact version of the high-definition oscillometric pressure monitor. It keeps the real-time oscillometric waveform and the accuracy of BPScan in a smaller, thinner form, powered solely over USB-C, without an internal battery. It is the option for those who prioritize portability and plug & play use connected to the computer or phone.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-27c7e244951b05cc451b","name":"Which systems or devices is it compatible with?","value":"“The BPScan S works over USB-C with laptops and PCs and with Android devices. It is not compatible with iOS or with ARM-architecture devices, so confirm the device you will use before purchasing. If in doubt, talk to a specialist to validate compatibility with your setup.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-38e596ca36fe57a1e119","name":"What is high-definition oscillometry?","value":"“It is the non-invasive method that records pressure oscillations as the cuff deflates. In high definition, you follow the measurement curve live, with the systolic, mean and diastolic markers, instead of trusting only the final number.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-df3c743838ed5aad062a","name":"What is the measuring range of the BPScan?","value":"“From 20 to 280 mmHg, with 1 mmHg resolution.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-cb4dc3de3f5b9c98d296","name":"What is the difference between BPScan and BPScan S?","value":"“The BPScan S is the compact version, with a USB-C connection. Both use the same INpulse One.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-50c5130b1183047a8e43","name":"Where do I see the results?","value":"“In INpulse One: curve, values and history go into the patient record. During monitoring, NIBP also feeds the digital anesthetic chart.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-4eb181f988c7d306-a-d8424ee636d9d5fd3567","name":"What affects measurement quality?","value":"“As in all veterinary oscillometry, choosing the cuff appropriate to the patient size and correct positioning are essential for accuracy.”"}],"@type":"Organization"}}