{"schemaVersion":"ready-scan.discovery-entity.v3","id":"urn:readyscan:entity:kendrick-laboratories-united-states-q64142796","slug":"kendrick-laboratories-united-states-q64142796","kind":"entity","entityType":"Organization","canonicalUrl":"https://directory.readyscan.ai/entities/kendrick-laboratories-united-states-q64142796","machineUrl":"https://directory.readyscan.ai/discovery/entities/kendrick-laboratories-united-states-q64142796.json","llmsUrl":"https://directory.readyscan.ai/entities/kendrick-laboratories-united-states-q64142796/llms.txt","name":"Kendrick Laboratories (United States)","alternateNames":[],"websiteUrl":"https://kendricklabs.com/","category":{"slug":"businesses","name":"Businesses","canonicalUrl":"https://directory.readyscan.ai/directory/businesses"},"description":"Company in Madison, United States.","summary":"Kendrick Laboratories (United States): Company in Madison, United States. Website: https://kendricklabs.com/","localizedDescriptions":[],"claims":[{"id":"content-native-digital-agencies-03c99a977af31885-a-4ae512af8155416e6a44","label":"Does 2D Western blotting work as well as 1D?","value":"“Yes, 2D works better because the proteins clumped together in a 1D band are further spread out in 2DE by isoelectric focusing. 2D WB is extremely sensitive and informative.”","sourceIds":["source-524d695dae7756da"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-f2b5dac202f6b77d3c90","label":"What is the sensitivity of your stains?","value":"“Every protein stains differently so it’s difficult to say exactly. Our in-house Coomassie blue stain is very sensitive, gives a fairly dark tropomyosin spot at 0.5 μg and a clearly discernible one at 100 ng. We find it’s roughly equal in sensitivity to the fluorescent stain Sypro Ruby.”","sourceIds":["source-524d695dae7756da"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-5abeefad7d34092eac61","label":"What is the maximum amount of protein and volume that can be loaded on a 2D gel?","value":"“In general for complex samples such as cell lysates run on SF gels, we suggest a maximum load of 200 μg for Coomassie blue or Sypro ruby staining and 50 μg for silver staining.”","sourceIds":["source-524d695dae7756da"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-7087e2cdd71061ac15a9","label":"How are pI and MW standardized?","value":"“Molecular weight (MW) markers listed below are loaded in a well on the right side (basic side) of the 2D gel in a well in the agarose that seals the tube gel to the slab gel.”","sourceIds":["source-524d695dae7756da"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-496546fef656b82fc0d2","label":"Do you accept radiolabeled proteins?","value":"“No. As of December 1, 2017 we will no longer accept radioactive samples.”","sourceIds":["source-524d695dae7756da"]},{"id":"source-description","label":"About","value":"Company in Madison, United States.","sourceIds":["source-9e306ff2c360076d"]},{"id":"source-listed-website","label":"Website","value":"https://kendricklabs.com/","sourceIds":["source-9e306ff2c360076d"]}],"knowledge":{"offerings":[],"answers":[{"id":"content-native-digital-agencies-03c99a977af31885-a-4ae512af8155416e6a44","question":"Does 2D Western blotting work as well as 1D?","answer":"“Yes, 2D works better because the proteins clumped together in a 1D band are further spread out in 2DE by isoelectric focusing. 2D WB is extremely sensitive and informative.”","sourceIds":["source-524d695dae7756da"],"claimIds":["content-native-digital-agencies-03c99a977af31885-a-4ae512af8155416e6a44"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-f2b5dac202f6b77d3c90","question":"What is the sensitivity of your stains?","answer":"“Every protein stains differently so it’s difficult to say exactly. Our in-house Coomassie blue stain is very sensitive, gives a fairly dark tropomyosin spot at 0.5 μg and a clearly discernible one at 100 ng. We find it’s roughly equal in sensitivity to the fluorescent stain Sypro Ruby.”","sourceIds":["source-524d695dae7756da"],"claimIds":["content-native-digital-agencies-03c99a977af31885-a-f2b5dac202f6b77d3c90"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-5abeefad7d34092eac61","question":"What is the maximum amount of protein and volume that can be loaded on a 2D gel?","answer":"“In general for complex samples such as cell lysates run on SF gels, we suggest a maximum load of 200 μg for Coomassie blue or Sypro ruby staining and 50 μg for silver staining.”","sourceIds":["source-524d695dae7756da"],"claimIds":["content-native-digital-agencies-03c99a977af31885-a-5abeefad7d34092eac61"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-7087e2cdd71061ac15a9","question":"How are pI and MW standardized?","answer":"“Molecular weight (MW) markers listed below are loaded in a well on the right side (basic side) of the 2D gel in a well in the agarose that seals the tube gel to the slab gel.”","sourceIds":["source-524d695dae7756da"],"claimIds":["content-native-digital-agencies-03c99a977af31885-a-7087e2cdd71061ac15a9"]},{"id":"content-native-digital-agencies-03c99a977af31885-a-496546fef656b82fc0d2","question":"Do you accept radiolabeled proteins?","answer":"“No. As of December 1, 2017 we will no longer accept radioactive samples.”","sourceIds":["source-524d695dae7756da"],"claimIds":["content-native-digital-agencies-03c99a977af31885-a-496546fef656b82fc0d2"]}],"developments":[]},"sources":[{"id":"source-record","title":"Kendrick Laboratories (United States) website","publisher":"kendricklabs.com","url":"https://kendricklabs.com/","accessedOn":"2026-10-24"},{"id":"source-524d695dae7756da","title":"kendricklabs.com/faq/","publisher":"kendricklabs.com","url":"https://kendricklabs.com/faq/","accessedOn":"2026-10-24","relatedPublicationsUrl":"https://readyscan.ai/sources/source-524d695dae7756da"},{"id":"source-9e306ff2c360076d","title":"wikidata.org/wiki/Special:EntityData/Q64142796.json","publisher":"wikidata.org","url":"https://www.wikidata.org/wiki/Special:EntityData/Q64142796.json?revision=2474494435","accessedOn":"2026-10-24","relatedPublicationsUrl":"https://readyscan.ai/sources/source-9e306ff2c360076d"}],"ownership":{"state":"public_sourced_unclaimed","notice":"Public-source record; owner verification is not claimed.","provenance":{"snapshotId":"kendrick-laboratories-united-states-q64142796-content-6872ab2abe8d7cdb-snapshot","sourceId":"ready-scan-subjects","sourceRecordId":"Q64142796","sourceRevisionId":"Q64142796:content:ba5769486e4b89ac","sourceContentHash":"fnv1a64:a06b8e9de44805dc","recordRevisionId":"Q64142796:content:ba5769486e4b89ac","recordContentHash":"fnv1a64:8d6a4badfa7d09a0","sourceCanonicalUrl":"https://kendricklabs.com/","sourceModifiedAt":"2026-10-24T16:25:38.710Z","observedOn":"2026-10-24","permission":{"basis":"public_information","evidenceUrl":"https://kendricklabs.com/"},"attributionUrl":"https://kendricklabs.com/"}},"datePublished":"2026-10-24","dateModified":"2026-10-24","contentFingerprint":"fnv1a64:4eeafdbc02defe93","revision":"fnv1a64:6a5bc175d3ae4e6c","agentProtocol":{"discovery":"https://readyscan.ai/api/v1/ai-search/discovery","evidence":"https://readyscan.ai/api/v1/ai-search/entities/kendrick-laboratories-united-states-q64142796/evidence"},"structuredData":{"@context":"https://schema.org","@id":"https://directory.readyscan.ai/entities/kendrick-laboratories-united-states-q64142796#entity","name":"Kendrick Laboratories (United States)","identifier":"urn:readyscan:entity:kendrick-laboratories-united-states-q64142796","description":"Company in Madison, United States.","url":"https://kendricklabs.com/","mainEntityOfPage":"https://directory.readyscan.ai/entities/kendrick-laboratories-united-states-q64142796","datePublished":"2026-10-24","dateModified":"2026-10-24","citation":["https://kendricklabs.com/","https://kendricklabs.com/faq/","https://www.wikidata.org/wiki/Special:EntityData/Q64142796.json?revision=2474494435"],"additionalProperty":[{"@type":"PropertyValue","propertyID":"ownership-state","name":"Ownership state","value":"public_sourced_unclaimed"},{"@type":"PropertyValue","propertyID":"content-fingerprint","name":"Material content fingerprint","value":"fnv1a64:4eeafdbc02defe93"},{"@type":"PropertyValue","propertyID":"source-record","name":"Source record","value":"ready-scan-subjects/Q64142796"},{"@type":"PropertyValue","propertyID":"source-revision","name":"Source revision","value":"Q64142796:content:ba5769486e4b89ac"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-03c99a977af31885-a-4ae512af8155416e6a44","name":"Does 2D Western blotting work as well as 1D?","value":"“Yes, 2D works better because the proteins clumped together in a 1D band are further spread out in 2DE by isoelectric focusing. 2D WB is extremely sensitive and informative.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-03c99a977af31885-a-f2b5dac202f6b77d3c90","name":"What is the sensitivity of your stains?","value":"“Every protein stains differently so it’s difficult to say exactly. Our in-house Coomassie blue stain is very sensitive, gives a fairly dark tropomyosin spot at 0.5 μg and a clearly discernible one at 100 ng. We find it’s roughly equal in sensitivity to the fluorescent stain Sypro Ruby.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-03c99a977af31885-a-5abeefad7d34092eac61","name":"What is the maximum amount of protein and volume that can be loaded on a 2D gel?","value":"“In general for complex samples such as cell lysates run on SF gels, we suggest a maximum load of 200 μg for Coomassie blue or Sypro ruby staining and 50 μg for silver staining.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-03c99a977af31885-a-7087e2cdd71061ac15a9","name":"How are pI and MW standardized?","value":"“Molecular weight (MW) markers listed below are loaded in a well on the right side (basic side) of the 2D gel in a well in the agarose that seals the tube gel to the slab gel.”"},{"@type":"PropertyValue","propertyID":"claim:content-native-digital-agencies-03c99a977af31885-a-496546fef656b82fc0d2","name":"Do you accept radiolabeled proteins?","value":"“No. As of December 1, 2017 we will no longer accept radioactive samples.”"},{"@type":"PropertyValue","propertyID":"claim:source-description","name":"About","value":"Company in Madison, United States."},{"@type":"PropertyValue","propertyID":"claim:source-listed-website","name":"Website","value":"https://kendricklabs.com/"}],"@type":"Organization"}}